Tower Inspection, Maintenance, and Repair


New Jersey, United States
Government : Military
RFP
Go to the link
This document has expired, therefore the above link may no longer work.

The U.S. Army Signal Network Enterprise Center (NEC) at Joint Base McGuire Dix Lakehurst (JBMDL) requires tower maintenance of seven communications towers, in accordance with ANSI/TIA-222-G standards. Three 40' towers located at the Contingency Operation Location (COL), Buildings 96167, 96168 and 96169 off Route 70 and Pinehurst Rd; one 100' tower located at 59C/Building 9456, one 100' tower located at Building 9013/Range Control Headquarters, one 100' tower located at Saw Mill/Building 5151, and one 125' tower located at old Pager Site/Building 3581. The maintenance and repairs include the following:

CONTINGENCY OPERATIONS LOCATION (COL) BUILDINGS 96167, 96168, 96169 TOWERS:
1. Base attachment points are collecting water and rusting. Water needs to be removed, filled with sand, sealed properly, and painted with heavy galvanizing compound to preserve hardware.
2. Ground wire connection clamps are insufficient and need to be replaced.
3. Remove and treat any rust that has accumulated on tower or at the base of tower and paint with heavy galvanizing compound to preserve hardware.
4. Replace any obstruction light lamps that are not functioning. Replacement light lamps must be incandescent for aviation purposes.
5.     Remove Safety -climb cables, they are not within OSHA specifications and standards that pose a safety hazard.
6. Replace antenna cables nylon ties with industrial standard electrical tape to secure cables properly.
7.     Replace any bent members on towers. One member is bent near the base on building 96168 tower.
8. Replace any missing bolts, and upgrade all tower bolts with stainless steel bolts.
9.     Furnish copies of all maintenance reports, and photos of existing towers to include photos of the above repairs that were completed for each tower with a description of each repair indicated in the photo.

SAWMILL BUILDING 5151 TOWER:
1. Diagonal member at 45 ft. is bent and rusting needs to be replaced.
2.     Foundation bolts are rusting and need to be painted with heavy galvanizing paint to preserve hardware.
3.     All Dish hardware needs to be painted with heavy galvanizing paint to preserve hardware.
4.     Replace obstruction light lamps with incandescent bulbs for aviation purposes.
5.     Furnish copies of all maintenance reports, and photos of existing tower to include photos of the above repairs that were completed for this tower with a description of each repair indicated in the photo.

RANGE 59 CHARLIE BUILDING 9456 TOWER:
1. Foundation bolts are rusting and need to be painted with heavy galvanizing paint to preserve hardware.
2. Dish hardware needs to be painted with heavy galvanizing paint to preserve hardware.
3. Replace obstruction light lamps with incandescent bulbs for aviation purposes.
4. Furnish copies of all maintenance reports, and photos of existing towers to include photos of the above repairs that were completed for this tower with a description of each repair indicated in the photo.

RANGE CONTROL HEADQUARTERS BUILDING 9013 TOWER:
1.     Base attachment points are collecting water and rusting. Water needs to be removed, filled with sand, sealed properly, and painted with heavy galvanizing compound to preserve hardware.
2.     Replace obstruction light lamps with incandescent bulbs for aviation purposes.
3.     Ground wire connection clamps are insufficient and need to be replaced.
4. Furnish copies of all maintenance reports, and photos of existing towers to include photos of the above repairs that were completed for this tower with a description of each repair indicated in the photo.

PAGER SITE BUILDING 3581 TOWER:
1. Foundation bolts are rusting and need to be painted with heavy galvanizing paint to preserve hardware.
2. Replace obstruction light lamps with incandescent bulbs for aviation purposes.
3. Furnish copies of all maintenance reports, and photos of existing towers to include photos of the above repairs that were completed for this tower with a description of each repair indicated in the photo.

This requirement 100% small business set-aside. This synopsis is provided for informational purposes and is not considered a request for quote. The solicitation will be posted on or about 23 June 2014. The offer due date will be stated in the solicitation. The solicitation and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-60. It is the responsibility of the offeror to review the web page for notice of amendments, updates, or changes to the solicitation. Please be advised that hard copies of the solicitation will not be made available; you must download solicitation documents from the FBO. All potential sources must obtain a DUNS number, a CAGE code, and register in the System for Award Management (SAM) located at https://www.sam.gov/portal/public/SAM/ in order to transact business with the government. Failure to obtain a DUNS number, a CAGE code and register in the SAM may result in the delay of award of a contract or possible award to the next otherwise successful offeror. For further information, please contact Katie Lyons, Contract Specialist at [email protected]