DISCREPANCY COMMENTS:
DISCREP: 19007 SSDG AIR SHUTDOWN DAMPENER OP IMPACT: MINIMAL- PARTS CAN BE REPLACED IN HOME PORT DURING NEXT CHARLIE PERIOD. MODERATE UPON FAILURE.
ETR: 102300ZJUN19
ASSIST: REQUEST SFLC TO PROCURE ALL PARTS NECESSARY AND SHIP TO HOMEPORT
REMARKS: WHILE MOORED AND ON GENERATOR POWER, THE PORT SHUTOFF AIR DAMPENER ON THE #2 SSDG SUDDENLY CLOSED CAUSING THE GENERATOR TO SECURE AND THE SHIP TO LOSE POWER. THE LATCH THAT HOLDS THE DAMPENER OPEN IS BECOMING WORN WHICH WILL MAKE THS MORE LIKELY TO HAPPEN IN THE FUTURE. Part not identified in MICA, cannot locate in FEDLOG, local Vendor: ZIEGLER CAT, 210 GARFIELD AVE. DULUTH, MN 55802, 218-722-6628.
PART(S):
1) P/N: 458-0426 SHUTOFF GP-A, NSN: Unknown, QTY: 01
STACEY V REID, CONTRACT SPECIALIST, Phone 5106375934, Email STACEY.V.REID@USCG.MIL