The RFP Database
New business relationships start here

Project 659-19-117 (VA-19-00055), Halls & Flooring Multiple Campus Buildings


North Carolina, United States
Government : Federal
RFP
Go to the link
This document has expired, therefore the above link may no longer work.

PRESOLICITATION NOTICE
Project # 659-19-117 Tunnel Halls & Flooring (Various Buildings)
The Department of Veterans Affairs, 1601 Brenner Ave Salisbury, NC has a requirement for a contractor to provide all labor, material, supplies, equipment, transportation, permits, license and qualified supervision for Project 659-19-119, to renovate multiple tunnels (halls & flooring) at the W.G. Bill Hefner VA Medical Center, Salisbury, NC.

General Scope: The Salisbury VAMC campus has multiple buildings connected by a ground floor tunnel/hallway system in varying stages of degradation. Sections are mismatched due to damage, past repairs and upgrades that have left uneven and worn floors and transitions, unsightly paint and marking schemes, and a general nondescript condition that cannot be corrected by routine maintenance. The intent of this comprehensive project is to replace the flooring and upgrade all finishes for a uniform, level, aesthetically pleasing and maintenance-friendly tunnel system for our patients and staff. The selected general contractor (GC) will provide all administration, supervision, labor, materials, tools and equipment, and perform all operations necessary to remove and replace the designated floors, transitions, handrails, wall guards, and cove base, and paint the hallways. Work will be performed according to project specifications and in accordance with current Salisbury VAMC construction policies, procedures and best practices.

Priority of Effort and Dimensions. The contractor shall be responsible for taking and applying accurate field measurements for the purposes of their proposals. Notify the COR of deviations greater or less than 10% of values specified below.

PRIORITY 1:B Bldg 2, Ground, 3400 sq ft, approx. 455 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint: B Pre-Catalyzed Epoxy, color TBD
Handrail:B InPro 900 series, wood grain, stainless steel
Wall Guard:B InPro 700 series
Ceiling:B ACT, color and style TBD

PRIORITY 2:B Bldg 5, Ground Floor, 2600 sq ft, approx. 325 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Handrail:B InPro 900 series, wood grain, stainless steel
Wall Guard:B InPro 700 series

PRIORITY 3:B Bldg 3, Ground Floor, 2300 sq ft, approx. 430 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Handrail:B InPro 900 series, wood grain, stainless steel
Wall Guard:B InPro 700 series

PRIORITY 4:B Bldg 4, Ground Floor, 2600 sq ft, approx. 480 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Handrail:B InPro 900 series, wood grain, stainless steel
Wall Guard:B InPro 700 series

PRIORITY 5:B Bldg 11, Ground Floor, 800 sq ft, approx. 100 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Handrail:B InPro 900 series, wood grain, stainless steel
Wall Guard:B InPro 700 series

PRIORITY 6:B Connecting Tunnel Bldgs 2 to 3, 1600 sq ft, approx. 185 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Wall Guard:B InPro 700 series

PRIORITY 7:B Connecting Tunnel Bldgs 2 to 4, 1000 sq ft, approx. 100 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Wall Guard:B InPro 700 series

PRIOIRTY 8:B Connecting Tunnel Bldgs 4 to 21, 3200 sq ft, approx. 375 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Handrail: InPro 900 series, wood grain, stainless steel
Wall Guard:B InPro 700 series

PRIORITY 9:B Connecting Tunnel Bldgs 4 to 11, 2200 sq ft, approx. 240 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Wall Guard:B InPro 700 series

PRIORITY 10:B Connecting Tunnel Bldgs 4 to 19, 2500 sq ft, approx. 225 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD
Wall Guard:B InPro 700 series

PRIORITY 11:B Connecting Tunnel Bldgs 2 to 5, 2200 sq ft, 120 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD

PRIOIRTY 12:B Connecting Tunnel Bldgs 5 to 7, 2100 sq ft, 200 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD

PRIORITY 13:B Connecting Tunnel Bldgs 5 to 6, 3300 sq ft, 320 lin ft
Flooring:B 5mm LVT, color and pattern TBD
Cove Base:B 6 Johnsonite rubber base, color TBD
Paint:B Pre-Catalyzed Epoxy, color TBD

*** Any areas excluded from the above will be detailed at the pre-bid meeting.



Estimated construction magnitude is between $500,000 and $1,000,000.
NAICS CODE: 236220 Size Standard: $36.5 Million
This solicitation is anticipated to be a Total Service Disabled Veteran Owned Small Business Set-Aside. Solicitation material will be available on/about June 24, 2019. Any specifications, drawings and amendments will be posted on this web site. Proposals will be due approximately 30 days after issuance of the solicitation. Location and points of contact for site visits will be identified in the solicitation.
This notice is for informational purposes only and is not a request for proposals. The Government is not obligated to issue a solicitation as a result of this notice. No other information is available until issuance of the solicitation. No bidders list is maintained. All interested vendors should register on this website. It is the offerors responsibility to check the web site periodically for any amendments/notices to the solicitation. Prospective contractors must be registered in the System for Award Management (SAM) database in order to obtain access in FedBizOpps. SAM and Vetbiz registration must be current and active to be eligible for contract award. Contractors please note: Online Representations and Certifications Applications (ORCA) apply to this solicitation. With ORCA; you now have the availability to enter and maintain your reps and certs with your proposal.
Any questions regarding this announcement and all future announcements regarding this project must be emailed to matthew.talley@va.gov. NO TELEPHONE REQUEST FOR BIDDING MATERIAL WILL BE ACCEPTED.

Matt Talley
Contracting Officer
704-638-9000 Ext. 15000