METAL BUILDING & COMPONENTS FOR A PREENGINEERED
METAL BUILDING.
BUILDING: 40' X 100' X 18', 1:12 PITCH,
GABLE STYLE; CLEAR SPAN.
GIRTS: BYPASS (SW) FLUSH (EW)
ENDWALLS: NON-EXPANDABLE RIGID FRAME
(LEW) AND BEARING FRAME (REW)
BAY SPACING: 5 @ 20'
LOADS/CODES: IBC2006, 98# MPH, 1#
COLLATERAL, 5# SNOW, 20 ROOF LIVE LOAD
(REDUCTION ALLOWED).
ROOF: NOT INCLUDED (BY OTHERS)
WALLS: 26 GAUGE PBR (STANDARD COLOR)
GUTTER & DOWNSPOUT: INCLUDED ON BOTH
SIDEWALLS
ACCESSORIES: (2) 3070, (2) 14 X 16 OVERHEAD
DOORS W/CHAIN DRIVE (TRACK STYLE)
SKYLIGHTS: NONE
INSULATION 3" VINYL-REINFORCED FOR
SHEETED WALLS (R-10) - 40' X 40'
PORTION ONLY
BASE CONDITION: NOT INCLUDED (BASE ANGLE
BY OTHERS)
BRACING: CABLE ALLOWED IN ROOF & SHEETED
PORTION OF SW
NOTE: 60' OF SIDEWALL OPEN TO REMAIN
OPEN, WITH 40' X 40' ENCLOSED.
SIX (6) SETS OF ENGINEERED SHOP DRAWINGS
ENGINEERED PLANS & ANCHOR BOLT PLANS
SUCCESSFUL VENDOR SHALL PROVIDE US WITH
PAINT COLOR SELECTIONS TO BE SELECTED BY
OWNER, BUILDING IS TO HAVE WALL
INSULATION PER PLANS AND SPECIFICATIONS
TRACK OVERHEAD AND PERSONNEL DOORS ARE
TO BE INCLUDED. ALL FRAMING AND TRIM
FOR OPENINGS TO BE INCLUDED. NO ROOF
PANELS, ROOF INSULATION, BASE ANGLE AND
INTERIOR WALL PANELS.