Inspect and Clean FWD and AFT Ventilation System - 688 Class Submarine


Connecticut, United States
Government : Military
RFP
Go to the link
This document has expired, therefore the above link may no longer work.

The Supervisor of Shipbuilding (SUPSHIP), Groton, CT intends to execute a contract to accomplish the cleaning of ventilation system fans 3 through 9, 12 through 21 and all ventilation ducting and chillers associated with these fans onboard a 688 Class Submarine. Baseline CO2 and O2 readings shall take place prior to starting any dry ice cleaning procedure on every accessible compartment on the vessel. All CO2 and O2 readings shall be taken before and after vent cleaning each day. CO2 and O2 readings shall be monitored and recorded continuously and in every accessible compartment on the vessel. Cleaning shall cease anytime CO2 readings exceed 3000 ppm or O2 level drops below 19.6%. When the cleaning process has been stopped, identify the deficiency and correct. Once corrected and CO2 readings are below 2000 ppm and O2 readings are above 19.6% then cleaning may be resumed. In addition to monitoring CO2 and O2 all standard shipboard safety procedures shall be followed. All companies providing dry ice cleaning shall have an approved vent cleaning procedure prior to start of any cleaning. NAVSEA Code 05Z42 and NSWCCD-SSES Code 921 must approve all procedures. All workers must possess a valid DOD clearance. The period of performance for this effort is 15 Sept 2014 through 15 Oct 2014.

Jack M. Berry, Phone 8604333156, Email [email protected]