The objective of this assignment is to provide domestic potable water to 64 homes
on Mt. Newton Cross Road and Senanus Drive. This involves the engineering, design,
construction supervision and tender administration for the supply and installation of
approximately 3000m of PVC watermain comprising of 1850m of 250mm PVC,
1120m of 150mm PVC with valves, fittings, a pressure reducing station and services
to designated properties. A pre-design study which includes conceptual routing,
water modeling and geotechnical investigation for the presence of bedrock along the
conceptual route has been completed and is available in PDF format on the Senanus
Road Watermain Extension webpage. Proponents should refer to Option 1,
Residential Demands as the baseline for design considerations as detailed in the
pre-design study. Fire flows or hydrants are not included in the scope of these works.
Flush valves are required for unidirectional flushing in place of hydrants.