FURNISH LEAD-IN CABLE WITH TWO CONDUCTORS OF NUMBER 14 AWG FABRICATED FROM STRANDED TINNED COPPER THAT
COMPLIES WITH IMSA SPECIFICATION 50-2 EXCEPT AS FOLLOWS: ENSURE CONDUCTOR PAIR IS TWISTED WITH A
MAXIMUM LAY OF 2.0 INCHES, RESULTING IN A MINIMUM OF 6 TURNS PER FOOT. PROVIDE A RIPCORD TO ALLOW CABLE JACKET TO BE OPENED WITHOUT USING A CUTTER.
PROVIDE LENGTH MARKINGS IN A CONTRASTING COLOR SHOWING SEQUENTIAL FEET AND WITHIN ONE PERCENT OF ACTUAL CABLE LENGTH. ENSURE CHARACTER HEIGHT OF THE MARKINGS IS APPROXIMATELY 0.10 INCH. PROVIDE CABLE THAT IS APPROVED ON THE DEPARTMENTS QUALIFIED PRODUCTS LIST (QPL).