BUILDING, MODULAR AS FOLLOWS:
12'X20' OFFICE BUILDING
IBC/AL CODED. 130 MPH WIND SPEED RATED
TIRES AND AXLES DETATCHED DURING
INSTALLATION, DETACHABLE HITCHES, OUTRIGGER
TYPE FRAME, STEEL IBEAMS
FLOOR: 2"X6" FLOOR JOISTS @ 16" O.C.,
NYLON IMPREGNATED BOTTOM BOARD, 5/8"
TOUNGUE AND GROOVE FLOOR DECKING, SINGLE
LAYER, 1/8" VCT BLOCK TILE THROUGHOUT,
R-19 INSULATION IN FLOOR.
WALLS: 2"X4", 16" O.C. WALL STUDS, 8'
FINISHED CEILING HEIGTH, DOUBLE TOP
PLATE ON EXTERIOR WALLS, 5/8" VINYL
COVERED GYSUM WALLS, EXTERIOR WALLS R13
KRAFT FACED INSULATION, STANDARD
INTERIOR TRIM PACKAGE, OPEN FLOOR PLAN.
ROOF: BOW TRUSS ROOF SYSTEM, TRUSS
SPACING AT 24" O.C., 20 PSF LIVE LOAD
ROOF, R30 KRAFT INSULATION, 7/16" FIRE
RATED ROOD SHEATHING, 45 MM BLACK EPDM
ROOF SYSTEM, SEA SPRAY FIXED CEILING.
PLUMBING: NONE
ELECTRICAL: 1 - 100 AMP SINGLE PHASE
BOX, COPPER ROMEX WIRING, 4- 4' DOUBLE
TUBE SURFACE MOUNTED LIGHTS W/ ELECTRIC
BALLAST FLORESCENT LIGHTS, 1-EXIT/
EMERGENCY COMBOLIGHT W/BATTERYPACK PER
CODE, 1 - PORCH LIGHT W/PHOTOCELL, 110V
RECEPTACLES W/STANDARS WHITE SWITCHES
AND COVER PLATES 12' O.C., 4-PHONE/DATA/
INTERCOMM/ALARM JBOX CONNECTIONS STUBOUTS
FOR FUTURE CONNECTIONS.
HVAC: 1- MIN 1TON WALLMOUNT HVAC SYSTEM
W/5 KW HEAT STRIP, 1- STANDARD THERMOSTAT,
CEILING SUPPLY DUCTED FIBERGLASS,
RETURN AIR THROUGH WALL AT UNIT.
EXTERIOR: .019 ALUMINUM OR HARDIE PANEL
EXTERIOR SIDING AND TRIM, EXTERIOR
SHEATHING, 100% STANDARD HOUSE WRAP
1-HEAVY DUTY STEEL DOOR 36"X80" WITH
10"X10" VISION PANEL, STANDARD CLOSER &
LEVER LOCKSET, MIN OF 2 EA - 24"X54" MIN
SIZE VERTICAL SLIDING WINDOWS INSULATED
W/VINYL MINI-BLINDS.
1 - 6'X6' LANDING W/ 30' ADA RAMP AND
5'X5'STEPS OF PRESSURE TREATED WOOD
BUILDING SKIRTING INCLUDED
ALL DELIVERY, INSTALLATION AND TRIM OUT
OF BUILDING MUST BE INCLUDED IN BID
PRICING.