Specifications:
1
Item must have towers with a minimum of 6 adjustable aluminum air nozzles for booth cabin
2
Item must have towers with the ability to be mounted vertically or horizontally in booth
cabin
3
Item must have source air drawn from tempered and filtered cabin air
4
Each tower must provide 500 f.p.m. of air movement at 6 feet from tower
5
Item must have intake filter remotely located from tower to filter air going into tower
6
Item must have High Efficiency blower fan remotely located on booth exterior and ducted
to tower
7
Item must have 1 per tower - 1 H.P. 208/440V 3-Phase fan motor
8
Item must have Laser Aiming device for accurate air stream placement
9
Item must provide controlled air flow - intentionally directed, focused air flow
10
Item must provide turbulent air flow - rapidly moving, multi-directional air flow
11
Item must have Electromechanical Control panel giving complete control over each
individual tower
12
Item must have internal activation switch installed inside booth for On/Off operation
13
Item must have overall dimensions of 10" x 60"
14
Item must not be intrusive to spray booth plenum in any manner
15
Item must not utilize unfiltered spray booth plenum air
16
Item must not be of an overhead ceiling mounted location
17
Item must have warranty of 1 year against any defects
18
Item must be compatible with existing Devilbliss Concept Cure Full Down Draft with heat
makeup and bake cycle style booth system
19
Supplier must provide user training at completion of installation
20
Installation of item must be included and unit must be installed to current codes
21
Delivery of item must be included
22
Item must not interfere with changing of any overhead booth filters
23
Item must not interfere with any of the current booth operations
24
Item must not interfere with the current fire suppression system mounted overhead in
booth
25
Item must meet minimum air flow requirements listed to properly dry waterborne paints